When Your Pump Was Tested on Water:Rigorous Correction Methods for Real-World Fluids

Almost every centrifugal pump datasheet you will ever receive was generated on a cold-water test rig. This post walks through exactly what changes when you run those pumps on hydrocarbons, viscous process fluids, slurries, or gases — and how to translate water-test data into accurate predictions for your actual service.

Why Water Is the Universal Test Fluid — and Why It Lies to You

Water at 20 °C is the most reproducible, inexpensive, well-characterised liquid on earth. Its density (998 kg/m³) and kinematic viscosity (~1.0 cSt) are tightly controlled in any ISO 9906-compliant test facility. Manufacturers test on water because they can guarantee measurement uncertainty within ±2% on head and ±3% on efficiency without extraordinary effort.

But "tested on water" creates a silent contract: the performance you see on the curve is only valid at ν ≈ 1 cSt, ρ ≈ 1000 kg/m³, with a fully single-phase, Newtonian, non-abrasive fluid. Step outside any one of those conditions and the curve is wrong — sometimes by a few percent, sometimes by 40%.

The correction problem breaks into four distinct regimes, each with its own physics and its own methodology:

Regime 1 — Viscosity

Viscous fluids thicken the boundary layers inside impeller passages, degrade head and efficiency, and shift BEP flow leftward. This is the most studied correction and has the most mature standards (HI 9.6.7, ISO 17769).

Regime 2 — Density & Vapour Pressure

Head in metres of fluid is density-independent; power is not. Volatile fluids demand NPSH derate for vapour pressure rise. The differential head curve stays identical in metres but shaft power scales directly with ρ.

Regime 3 — Slurry / Solids-Bearing Fluids

Solid particles increase apparent density, raise viscosity, cause abrasion-driven hydraulic degradation, and trigger stratification or blockage at off-design flows. This is the least standardised regime.

Regime 4 — Gas / Two-Phase Flow

Even small gas fractions (>2–3%) cause head breakdown via gas accumulation in the impeller eye. Multiphase correction factors are empirical and highly geometry-dependent.

Regime 1: Viscosity Correction — The HI 9.6.7 / ISO 17769 Method

This is the most consequential correction in everyday refinery and chemical plant work. The mechanism is straightforward: higher viscosity increases the skin-friction losses in the narrow curved passages of the impeller and diffuser, while the leakage and disc friction losses also change. Net effect — head drops, flow at BEP shifts, and efficiency falls dramatically.

The Hydraulic Institute Method (2010, replaces the old 1948 chart method)

HI 9.6.7 defines four correction factors derived from an extensive empirical database covering radial-flow pumps tested on viscous fluids:

HI 9.6.7 Correction Factors
Q_visc = C_Q × Q_w [m³/h or gpm]
H_visc = C_H × H_w [m or ft]
η_visc = C_η × η_w [—]
P_visc = (ρ_fluid/ρ_w) × (Q_visc × H_visc) / (367 × η_visc) [kW]

The correction coefficients C_Q, C_H, and C_η are themselves functions of three dimensionless groups. HI expresses them through a parameter called B*, which combines the BEP flow rate, the single-stage head at BEP, the number of stages, and the kinematic viscosity of the process fluid:

HI B* parameter (the viscosity correction Reynolds group)
B* = (ν_fluid^0.5 × Q_BEP^0.25) / (H_BEP,1stage^0.375)

where:
ν_fluid = kinematic viscosity of process fluid [m²/s × 10⁶ = cSt]
Q_BEP = BEP flow rate from water curve [m³/s]
H_BEP,1st = single-stage BEP head on water [m]

Once B* is computed, the three correction coefficients are read from the HI 9.6.7 figures (or computed via the polynomial fits provided in Appendix B of the standard). The figures plot C_Q, C_H(at 0.6Q, 0.8Q, 1.0Q, 1.2Q), and C_η against B*, and each has been validated against the test database for 1 cSt ≤ ν ≤ 3000 cSt.

Designer's note: The HI method is statistically derived from a wide population of pumps, not from any single manufacturer's geometry. For a specific pump — particularly one with an unusually wide or narrow impeller (b₂/D₂ outside the mainstream range), or a pump specifically optimised for viscous service — the actual corrections can deviate from HI by ±10 to ±15%. Always validate against factory test data at one viscosity point if the service is critical.

The ISO 17769 Approach and Where It Differs

ISO 17769-1 (2012) takes a slightly different route. It defines a viscosity correction Reynolds number Re_visc and correction functions f_H, f_Q, f_η. The key distinction is that ISO accounts for the impeller specific speed n_q explicitly, which HI does not:

ISO 17769 — Impeller specific speed (SI)
n_q = n × Q_BEP^0.5 / H_BEP^0.75

Valid range: 6 ≤ n_q ≤ 45 (radial-flow only)
Outside this range: method accuracy degrades — use CFD or test data.

For n_q below ~20 (low-specific-speed, high-head-per-stage pumps), the ISO method predicts more conservative (larger) head derates than HI. For n_q above ~35 (mixed-flow pumps), ISO predicts less correction than HI. In practice, for a typical single-stage process pump (n_q ≈ 25–35) handling crude oil at 50–200 cSt, both methods converge to within 3–5% of each other.

Step-by-Step Worked Correction — Example

Consider a single-stage API 610 OH2 pump, water-test data: Q_BEP = 120 m³/h, H_BEP = 65 m, η_BEP = 74%, n = 2950 rpm. Process fluid: crude oil at 40 °C, ν = 85 cSt, ρ = 870 kg/m³.

  • 1 Compute B*: ν = 85 cSt, Q = 120/3600 = 0.0333 m³/s, H = 65 m.
    B* = (85^0.5 × 0.0333^0.25) / (65^0.375) = (9.22 × 0.427) / 5.25 = 0.749
  • 2 Read HI 9.6.7 charts at B* = 0.749: C_Q ≈ 0.95, C_H(1.0Q) ≈ 0.92, C_η ≈ 0.72.
  • 3 Corrected operating point: Q_visc = 0.95 × 120 = 114 m³/h; H_visc = 0.92 × 65 = 59.8 m; η_visc = 0.72 × 0.74 = 53.3%
  • 4 Shaft power on oil: P = (870/1000) × (114 × 59.8) / (367 × 0.533) = 30.2 kW vs. 19.9 kW on water at BEP. Note: power actually increases despite head and flow loss — a critical insight for motor sizing.
  • 5 Recalculate full corrected H-Q curve using C_H values at 0.6Q, 0.8Q, 1.0Q, 1.2Q to reconstruct the entire viscous operating range.
114 m³/h
Corrected BEP flow (vs 120)
59.8 m
Corrected BEP head (vs 65)
53.3%
Corrected efficiency (vs 74%)
+52%
Shaft power increase on oil
Common mistake: Engineers often apply viscosity correction to head in metres and forget that shaft power goes up even when head and flow go down. Undersized motors and overloaded cables are a direct consequence of skipping step 4. Always recompute power on the corrected curve, not the water curve.

Limits of Applicability — When the Method Fails

Condition Why the method breaks What to do instead
ν > 3000 cSt Boundary layer completely fills impeller passages; flow becomes laminar throughout — empirical data does not extend here. Use positive-displacement pump. If centrifugal is mandatory, obtain vendor-specific test data.
Non-Newtonian fluid (slurries, polymers, gels) Apparent viscosity is shear-rate dependent; the single-viscosity B* input becomes meaningless. Use apparent viscosity at the impeller tip shear rate: γ̇ ≈ 2πnD₂/(60 × b₂)
n_q < 6 or > 45 Correlation was not fitted outside this range. Reduce to validated n_q via impeller trimming or staging, or test at actual viscosity.
Multi-stage pumps (>5 stages) Inter-stage leakage paths interact; correction factors do not stack simply. Apply single-stage correction then multiply by stage count — conservative approach.

Regime 2: Density and Vapour Pressure Corrections

This is the most misunderstood area, because engineers confuse head (which is in metres, density-independent) with pressure rise (which is density-dependent).

The Head–Pressure Relationship

Fundamental head-pressure identity
ΔP = ρ × g × H

H [m] is identical on water and on any other Newtonian fluid of the same viscosity.
ΔP [Pa or bar] scales linearly with process fluid density ρ [kg/m³].

So if your pump is specified to deliver 6.0 bar differential pressure in crude oil service (ρ = 870 kg/m³), the required head is H = 6.0×10⁵ / (870 × 9.81) = 70.3 m. You size the pump using the water-test H-Q curve at 70.3 m, with no head correction at all — as long as viscosity is similar to water. This is exactly why all pump datasheets quote head in metres, not bar.

Shaft Power and Density Scaling

Power scaling with density
P_fluid = P_water × (ρ_fluid / ρ_water)

At identical H [m] and Q [m³/h], power scales exactly with ρ.
A pump delivering 100 kW on water will consume 87 kW on petroleum naphtha (ρ=680)
but 125 kW on sulphuric acid (ρ=1840 kg/m³).

Motor and driver sizing for dense fluids (brine, acid, caustic, molten salt) frequently catches engineers by surprise. A pump driving an electric motor that is fine on water can trip its overload relay when switched to a dense process fluid, even with no viscosity change whatsoever.

NPSH Correction for Volatile Fluids

NPSH (Net Positive Suction Head) is one of the most poorly understood parameters in pump practice. The NPSH_R (required) published on the datasheet is a water-test value, measured at 3% head drop. For hot water or volatile hydrocarbons, the actual available NPSH_A is reduced by the vapour pressure of the fluid:

NPSH_A at suction flange
NPSH_A = (P_s - P_v) / (ρg) + V_s²/2g

P_s = static pressure at suction flange [Pa abs]
P_v = vapour pressure of fluid at suction temperature [Pa abs]
V_s = mean velocity at suction flange [m/s]

For services above ~80 °C, or for light hydrocarbons (LPG, propane, butane, pentane), the vapour pressure correction can eliminate 5–15 m of available NPSH. A pump with NPSH_R = 4.5 m on water may cavitate severely on propane at 20 °C (P_v ≈ 8.4 bar abs) unless the suction system provides adequate static head.

Thoma cavitation parameter σ: For preliminary suction system design, use σ = NPSH_R / H_total. A well-designed impeller suction geometry targets σ ≈ 0.06–0.15 for radial pumps. If your system NPSH_A / H is below this, re-examine suction vessel elevation, suction pipe diameter, or pump type selection before adjusting the pump itself.

The NPSH Reduction Factor for Hot Liquids (B-Factor)

In hot-water, boiler feed, or condensate service, the NPSH_R can actually be less than the cold-water test value. This counterintuitive result arises because partial evaporation inside the impeller eye absorbs energy that would otherwise collapse cavitation bubbles. The Hydraulic Institute provides an NPSH reduction chart (based on the Stepanoff B-factor method) that quantifies this derate:

Stepanoff B-factor (simplified)
B = (h_fg × ρ_v) / (c_p × ρ_l × T)

h_fg = latent heat of vaporisation at T [J/kg]
ρ_v = vapour density at T [kg/m³]
ρ_l = liquid density at T [kg/m³]
c_p = specific heat capacity [J/kg·K]
T = absolute temperature [K]

NPSH_R,effective ≈ NPSH_R,cold × (1 - Σ)

For boiler feed applications above 120 °C, the NPSH reduction factor Σ can reach 0.5–0.7, meaning you need only 30–50% of the cold-water NPSH_R. However, applying this reduction requires verified impeller geometry and is never recommended without manufacturer endorsement — the risk of underestimating cavitation in high-enthalpy service is severe erosion of the impeller inlet in days rather than years.


Regime 3: Slurry Service — The Most Underestimated Derate

Slurry pumping combines at least three simultaneous performance penalties: increased apparent density, apparent viscosity effects, and mechanical head degradation due to particle interactions with the impeller surfaces. The worst of these is often the last.

Apparent Density of a Slurry

Slurry mixture density (homogeneous model)
ρ_m = C_w × ρ_s + (1 - C_w) × ρ_l
or equivalently:
ρ_m = 1 / (C_w/ρ_s + (1-C_w)/ρ_l) [volume-fraction form]

C_w = solids mass fraction; ρ_s = solids density; ρ_l = carrier liquid density

The mixture density is straightforward. What is not straightforward is what happens to head and efficiency.

The Head Ratio HR and Efficiency Ratio ER

Extensive testing — notably by Cave (1976), Sellgren (1990s), and Wilson et al. at the GIW Hydraulic Laboratory — has shown that slurry degrades pump head in metres by a factor HR < 1.0, independent of density. This is a hydraulic effect caused by particle interactions with the boundary layer and energy transfer within the impeller passage. HR and ER are empirically defined as:

Slurry head and efficiency ratios
HR = H_slurry / H_water (at same shaft speed and flow rate)
ER = η_slurry / η_water

Empirical correlation (Sellgren-Wilson, for d_50 < 1mm):
HR = 1 - (0.01 × C_v × (ρ_s/ρ_l - 1)^0.7 × (V_tip/V_ref)^-0.5)

C_v = volumetric concentration; V_tip = impeller tip speed [m/s]; V_ref = 10 m/s

Typical HR values for phosphate slurry at 30 wt% concentration range from 0.88 to 0.94. For fine coal slurry at 40 wt%, HR can drop to 0.82. These corrections compound with density: shaft power increases both because ρ_m > ρ_water AND because more shaft work is needed per unit head delivered.

Critical Velocity — The Deposition Constraint

Below a critical slurry velocity in the impeller and casing, particles settle and cause blockage, severe vibration, and catastrophic erosion at localised points. The Durand-Condolios critical velocity for pipe flow is modified for pump impeller passages:

Durand deposition velocity (adapted for pump internal passages)
V_c = F_L × [2gD_h × (ρ_s/ρ_l - 1)]^0.5

F_L = Durand factor, function of d_50 and C_v (typically 0.9–1.8)
D_h = hydraulic diameter of impeller passage at narrowest point [m]

The practical implication: slurry pumps must not be operated below approximately 60% of BEP flow. The runout end of the curve at 120–130% BEP is equally dangerous due to recirculation-induced particle impingement in the suction. The allowable operating region for slurry service is far narrower than for clean liquid.

Material selection interacts with performance: Chrome iron (27% Cr white iron, 650–700 BHN) is standard for abrasive slurry. Rubber lining shifts the optimum C_d × V_tip product. Importantly, a rubber-lined pump will show 2–4% less peak efficiency than a chrome iron equivalent at the same flow, but the lower coefficient of restitution for rubber reduces erosion rate by an order of magnitude in fine slurry service. This must be accounted for in your efficiency budget.

Regime 4: Two-Phase Gas-Liquid Flow

Even a small free-gas fraction causes disproportionate performance loss in centrifugal pumps. The mechanism is gas accumulation at the low-pressure region near the impeller eye, where the gas phase expands into a contiguous pocket that blocks flow. This is categorically different from the inception of cavitation — it can occur with non-condensable gas (air, CO₂, H₂S) at pressures well above vapour pressure.

Gas Volume Fraction and Head Breakdown

In-situ gas volume fraction at pump suction (αₛ)
α_s = Q_g / (Q_g + Q_l)

Q_g = free gas flow rate at pump suction conditions [m³/s]
Q_l = liquid flow rate [m³/s]

Rule of thumb — head degradation onset:
α_s < 0.02 → Correction <5%, negligible for most purposes
0.02 < α_s < 0.06 → Head derate 5–25%, apply Cirilo/Sachdeva correction
α_s > 0.06–0.10 → Head breakdown possible, especially at low n_q < 25

The Cirilo (1998) empirical model, validated on ESP (Electric Submersible Pump) data and since extended to surface centrifugals, relates the head ratio H_2ph / H_liquid to the in-situ gas fraction, the gas-to-liquid density ratio, and a pump-specific degradation coefficient A_g that must be calibrated against actual pump geometry. For a first estimate:

Two-phase head correction (Cirilo simplified form)
H_2ph = H_liquid × exp(-A_g × α_s / (1 - α_s))

A_g typically ranges from 0.40 (axial-inducer entry, high n_q) to 1.80 (standard radial, no inducer)
H_liquid = head at same flow on single-phase liquid (water-corrected)

Mitigation: Inducers and Gas-Tolerant Impeller Design

An axial inducer upstream of the first-stage impeller dramatically extends gas-handling capability. A well-designed inducer (typically 2–3 helical blades, low solidity, 10–15° helix angle) creates a region of high centrifugal separation that sweeps the gas radially outward before it reaches the impeller eye. With an inducer, gas tolerance typically extends from α_s < 0.06 to α_s < 0.15–0.20 before significant head breakdown. The inducer adds its own NPSH_R contribution (~1.5–2.5 m for a typical geometry), so this is not a free trade — NPSH_A must be verified independently for the combined inducer-impeller system.


Building a Corrected Performance Map: Putting It All Together

In practice, most process services involve more than one correction simultaneously. A crude oil transfer pump may face elevated viscosity, density different from water, and small free-gas fractions from dissolved gas breakout. The corrections are applied in sequence, not in parallel:

  • 1 Start from the certified water-test H-Q-η-P curve (ISO 9906 Grade 1 or 2 acceptance). Never start from published catalogue curves — tolerance bands are too wide.
  • 2 Apply viscosity correction (HI 9.6.7) to obtain the viscous H-Q and η-Q curves, as described in Section 2 above. This is the dominant correction for most refinery and chemical services.
  • 3 Scale head curve for the required pressure duty using ΔP = ρ × g × H. No head correction if ν is water-like; apply full viscosity correction if ν > ~10 cSt.
  • 4 Check NPSH_A > NPSH_R × 1.10 (HI recommended margin) at the minimum suction pressure condition, with vapour pressure correction for fluid temperature and composition.
  • 5 Apply slurry HR correction if C_v > ~5% solid content. Multiply corrected head by HR, and verify V_min > V_c throughout the intended operating range.
  • 6 Compute shaft power on actual fluid: P = ρ_m × Q × H × g / η_corrected. Verify against motor nameplate with a 10% service factor minimum.
  • 7 Check two-phase gas fraction. If α_s > 2%, apply gas derate and consider inducer addition or pump resizing to a higher-n_q geometry with inherently better gas-handling.
Sequence matters: Always apply viscosity correction before you scale for density. Applying them in reverse order introduces a small but compounding error because viscosity correction is calibrated against water-test BEP parameters, not against the pressure-scaled operating point.

Special Cases: Polymer Solutions and Pseudoplastic Fluids

Polymer solutions (polyacrylamide, CMC, xanthan gum) exhibit shear-thinning behaviour — viscosity decreases with increasing shear rate. Neither the HI nor the ISO method directly applies, because both assume Newtonian behaviour with a single representative viscosity.

The approach I recommend, supported by work from Gülich (Centrifugal Pumps, 3rd ed., 2014), is to calculate an effective viscosity at the characteristic shear rate inside the impeller. The relevant shear rate in an impeller passage is approximately:

Effective shear rate in impeller passage (Gülich, 2014)
γ̇_eff = C_γ × u₂ / b₂

u₂ = impeller tip speed [m/s] = π × D₂ × n / 60
b₂ = impeller outlet width [m]
C_γ = empirical constant ≈ 4–8 (varies with specific speed and passage geometry)

The power-law or Carreau model is then used to convert γ̇_eff into ν_eff, which is substituted into the HI B* parameter. This approach has been validated for n_q between 15 and 45 with reasonable accuracy (±12%) for polymer concentrations up to ~1000 ppm in water — the range typical of polymer flooding in oil production.

For concentrations above this, or for Bingham plastic fluids (drilling muds, cement slurries), the flow regime inside the impeller is fundamentally altered, and empirical correction methods become unreliable. Dimensional analysis using the generalized Reynolds number for non-Newtonian flow in curved passages is required, and this is frankly still an active area of research.


Temperature Effects Beyond Viscosity

Temperature changes several fluid properties simultaneously, and each affects pump behaviour differently. This is rarely treated holistically:

Property change with temperature Effect on pump performance Dominant at
Viscosity ↓ (most liquids) Approaches water curve; efficiency recovers, BEP shifts rightward All viscous services above ambient
Density ↓ Shaft power ↓ proportionally; pressure rise ↓ at same head Services above ~80 °C
Vapour pressure ↑ NPSH_A ↓; cavitation risk increases Services above ~60 °C or with light components
Surface tension ↓ Cavitation bubbles collapse more violently; erosion risk increases at same NPSH margin High-temperature water, light hydrocarbons
Thermal expansion of casing Running clearances change; axial float must be designed for T_min to T_max range Cryogenic and high-temp (>150 °C) services

The interaction between vapour pressure and NPSH deserves particular attention in condensate and boiler feed pump sizing. The NPSH_A must be computed at the worst-case combination of minimum suction vessel level, maximum fluid temperature (highest vapour pressure), and minimum system pressure — not at the nominal condition. I have reviewed numerous pump failures attributed to "unexplained cavitation" that were simply the result of computing NPSH_A at the nominal operating point instead of the worst-case transient.


Validation Strategy: How to Build Confidence in Your Corrected Curve

Corrections are only as good as the data and models they rest on. In critical services, corrections alone are insufficient — you need a validation hierarchy:

Tier 1 — Vendor viscous test (highest confidence)

Request factory performance testing at actual viscosity using a calibrated viscous test loop. Cost: significant but justified for large capital pumps (>500 kW) or novel fluid services. Uncertainty: ±3–5%.

Tier 2 — Scale-model testing

Test a geometrically similar smaller pump at the same Reynolds number (same Re = u₂D₂/ν). Scale head by velocity ratio squared, power by density and velocity ratio cubed. Uncertainty: ±5–8% after Froude and Re scaling.

Tier 3 — CFD simulation

RANS CFD with appropriate turbulence closure (SST k-ω for separated flows) and correct fluid properties. Can predict viscosity effects well for n_q 15–45, ν up to ~500 cSt. Uncertainty: ±5–10% on absolute efficiency, better on relative trends. Not a substitute for test in slurry or two-phase service.

Tier 4 — Applied correction standards (minimum)

HI 9.6.7 / ISO 17769 applied per the methodology above. Acceptable for preliminary engineering, motor sizing, and moderate-duty applications. Uncertainty: ±10–15% on efficiency, ±5–8% on head/flow.


Key Takeaways for the Practising Engineer

A distillation of the above into actionable rules for daily pump selection and specification work.

  • 1 Head in metres is (almost) fluid-independent for Newtonian liquids near water viscosity. Pressure is not. Always convert your duty pressure to metres using process fluid density before entering the H-Q curve.
  • 2 Viscosity correction is non-trivial above ~5 cSt and dominant above 50 cSt. Never specify a motor at water-test shaft power for a viscous service — power almost always increases.
  • 3 NPSH_A must be computed at worst-case process conditions (maximum temperature, minimum vessel level, minimum suction pressure). Build in at least 0.5–1.0 m margin beyond HI's recommended 10% over NPSH_R.
  • 4 Slurry service requires explicit HR and ER derating. Verify that minimum flow exceeds critical deposition velocity throughout the control range, not just at design flow.
  • 5 Two-phase gas handling requires active design attention above α_s = 2%. An inducer is the most reliable mitigation for α_s up to 15–20%.
  • 6 Non-Newtonian fluids cannot be corrected by HI/ISO directly — use effective viscosity at the impeller shear rate as a substitute input to the standard method, and recognise the increased uncertainty.
  • 7 For every critical service, demand the original certified test curve, not a catalogue curve. Corrections applied to a ±10% tolerance catalogue curve are meaningless.

References: HI 9.6.7-2010 (Viscosity Corrections for Centrifugal Pumps); ISO 17769-1:2012; Gülich J.F., Centrifugal Pumps, 3rd ed., Springer, 2014; Wilson G. et al., Pump Handbook, McGraw-Hill, 4th ed., 2008; Sellgren A. & Wilson G., Solids-Handling Pumps, BHR Group, 1999; Cirilo R., Air-Water Flow Through ESP Stages, SPE 36069, 1998.

Working on a Challenging Engineering Project?

DESiM Innovations supports organizations developing advanced products in turbomachinery, pumps, compressors, turbochargers, gas turbines, microturbines, and distributed energy systems.

Our capabilities include New Product Development (NPD), engineering design, simulation, performance analysis, product validation, and custom software development to help accelerate development and solve complex engineering problems.

If you are looking for engineering expertise or software solutions for your next project, we would be happy to discuss your requirements.

Contact Us

Leave a Reply

Your email address will not be published. Required fields are marked *

Share Across Platforms

DESiM Innovaions (OPC) Private Limited

Engineering Consultancy & Software Solutions, All in One Place

Edit Template

Latest Posts

Engineering Services

Advanced simulation and technical analysis services designed to power your engineering excellence.

DESiM Innovations (OPC) Private Limited

No 21, 3rd Floor, Ramachandra Arcade, Ramaiah College Road, (Above ICICI Bank Mathikere Branch) Mathikere, Bangalore 560054 Karnataka India.

Recent news

  • All Post
  • Blog
  • Case Studies
  • Technical Publications
    •   Back
    • Turbomachinery
    • Thermodynamics
    • OpenFOAM
    • Meshing
    • Kompas-3D
WhatsApp
Need help? Let's chat! 💬 ×
DESiM Assistant
Engineering & Simulation Assistant
1

Enter your details to download brochure

Enter your details to access the brochure.